Type | Monitor for displacement | Monitor for velocity | Monitor for acceleration |
---|
VM-90 MED | VM-90 MEV | VM-90 MEA |
---|
Frequency range | 15 to 500 Hz +0.5 dB -3 dB 20 to 500 Hz ±0.5 dB | 15 to 1,000 Hz +1 dB -3 dB 20 to 850 Hz ±1 dB | 10 to 8,000 Hz ±3 dB 20 to 5,000 Hz ±1 dB |
---|
Measurement range (full scale) *1 | Select from 0 to 20 μmp-p, 0 to 50 μmp-p, 0 to 100 μmp-p, 0 to 200 μmp-p, 0 to 500 μmp-p | Select from 0 to 1 mm/s, 0 to 2 mm/s, 0 to 5 mm/s, 0 to 10 mm/s, 0 to 20 mm/s, 0 to 50 mm/s | Select from 0 to 1 m/s2, 0 to 2 m/s2, 0 to 5 m/s2, 0 to 10 m/s2, 0 to 20 m/s2, 0 to 50 m/s2, 0 to 100 m/s2 |
---|
Alarm step | 2 steps |
---|
DC output (for recorder) | 4 to 20 mA (at the load 0 to 300 Ω) 1 to 5 V (100 kΩ or more, 250 Ω connection to outside) |
---|
Alarm action | Activated over alarm setting value (time constant : approx. 3 seconds) |
---|
Ararm setting range | Possible to set 10 to 100% of full scale |
---|
Alarm contact | 1C contact for each alarm |
---|
Alarm contact capacity | AC250 V 3.0A/DC24 V , 3.0 A (at resistive load) |
---|
Alarm reset | Automatic |
---|
Operating temperature/ humidity range | 0 to 50 ゚C 0 to 85%RH (Non-condensing) |
---|
Power supply | AC100 V or 110 V *2 (+10%/-15%), 50/60 Hz |
---|
Power consumption | 15 VA or less |
---|
Size/Mass | 200 (W) x 103 (D) x 105 (H) mm (excluding connectors etc.) /2 kg |
---|