Home | Contact | Sitemap | Admin
  • > 소음•진동 관련기기
  • > 진동모니터
  • > IMV CORPORATION
  • > Vibrations
  • > Vibration Monitoring Systems
Contact Sensor Type Vibration Monitoring System
Art.-No. VM-9301 Series
모델명 Art.-No. VM-9301 Series
제조사 IMV CORPORATION
원산지 일본
분류명 Vibrations

* Specifications


TypeVM-9301 seriesVM-9301A series
PickupElectrodynamic velocity pickupPiezoelectric accelerometer
Amplifier
unit type
Type 1 line:VA-9301(1-I)
Select velocity or displacement
Type 2 line:VA-9301(2-I)
Simaltaneous measurement of velocity and displacement
Type 1 lineVA-9301A(1-I)
Select acceleration, velocity or displacement
Type 2 line:VA-9301A(2-I)
Simaltaneous measurement of any two of acceleration, velocity or displacement
Frequency
range
Low: 5 to 500Hz (-11 to +6%)
Medium:10 to 500Hz (-11 to +6%)
Filter selectable (pass band)
High-pass filter:5, 10, 15, 20, 50, 100Hz
Low-pass filter:20, 50, 100, 200, 500Hz
5 to 10kHz (-30 to +6%)
Filter selectable (pass band)
High-pass filter:5, 10, 20, 50, 100Hz
Low-pass filter:100, 200, 500, 1k, 5k, 10kHz

(High-pass filter : 20Hz- in case of displacement
        or velocity
Low-pass filter : -500Hz in case of displacement,
        -1kHz in case of velocity)

Measurement
range
Displacement50, 100, 150, 200, 300, 500, 999 (1,000) μmP-P100, 150, 200, 300, 500, 999 (1,000) μmP-P
Velocity10, 15, 20, 30, 50 mm/s10, 15, 20, 30, 50 mm/s
Acceleration-10, 15, 20, 30, 50, 100, 150, 200, 300, 500 m/s2
Equipment
failure
Indication
lamp
Orange LED located on the upper part of amplifier front panel [FAT]
Secondary power is lit at ubnormal condition.
Alarm
contact
1a contact (open at normal condition) operate under fuse melting, power switch shut off and primary / secondary power failure
Alarm resetSelect from automatic or manual recovery
Pickup
cable
break
alarm
Indication
lamp
Green LED located on the upper part of amplifier front panel [PU]
Lights-out when wire is broken (lights-on at normal condition)
(When pickup connected with charge amplifier is used, this function is not valid.)
Alarm
contact
Standard:1a contact *available 1b or 1c (open at normal condition, closed when wire is broken) operate when pickup cable is broken.
Alarm resetSelect from automatic or manual recovery
AlarmAlarm stepType 1 line:upper limit 2 steps Alarm (ALM) / Trip (TRP)
Type 2 line:upper limit 1 step Alarm1 (ALM1,1lline), Alarm2(ALM2, 2line)
Delay timerSelect from 0 to 15 sec. by the slide switch inside of the amplifier unit (0 sec. if not specified.)
Setting
extent
5.0 to 99.9% (can be set at 0.1% intervals)
(When alarm function is not used 99.9% is set. Indication lamp and contact is on at over fullscale value)
Indication
lamp
Type 1 line:Orange LED [ALM], red LED [TRP]
Type 2 line:Orange LED [ALM1], red LED [ALM2]
Alarm
Contact
Select from “ALM / ALM1 circuit:2a contact TRP / ALM2 circuit 2a contact” or
“ALM / ALM1 circuit:1b1a contact TRP / ALM2 circuit 1a1b contact”
Contact capacityAC110 V 2 A (DSP Relay made by Panasonic) DC110 V 0.2 A
Alarm resetSelect from automatic (Hysteresis 3%) or manual recovery
Rectification
level
output
DC
output 1
Select from DC4-20mA (insulation output), Loading 500Ω or less or
DC1-5 V (insulation output), Loading 100kΩ or more
DC
output 2
Select from DC4-20mA (insulation output), Loading 500Ω or less or
DC1-5 V (insulation output), Loading 100kΩ or more
Waveform
output
Pickup
waveform
output
AC±10mV /(mm/s) or AC±17.5mV /(mm/s),
Loading 100kΩ or more
(Depending on specifications of pickup)
AC±5mV/(m/s2), Loading 100kΩ or more
(Depending on specifications of pickup)
Waveform
output
AC±5V(at the full-scale), Loading 100kΩ or more
Panel meterRed LED three-digit indication, [9.9.9] is displayed at over 120% of full-scale
Operating temperature/
humidity range
0 to 50 °C, 20 to 95%RH, wet bulb temperature is 35°C (non-condensing)
Power supplyAvailable range AC85 to 264V, 47 to 66Hz
Power
consumption
20VA or less (1CH), 30VA or less (3CH), 45VA or less (6CH), 60VA or less (9CH), 75VA or less (12CH)
At AC100V (Depends on the number of amplifier or power supply)
Painting colorMunsell 5Y7/1, half matted
MassApprox. 2.0kg (1CH), approx. 3.9kg (3CH), approx. 5.9kg (6CH), approx. 8.2kg (9CH),
approx. 10.2kg (12CH)