Home | Contact | Sitemap | Admin
  • > 소음•진동 관련기기
  • > 지진계•센서
  • > IMV CORPORATION
  • > Seismometer
  • > Seismometer
Seismic Monitoring System
SW-74
모델명 SW-74
제조사 IMV CORPORATION
원산지 일본
분류명 지진계

 

Model

SW-74

Display Element

STN monochrome LCD with touch switch
(back light color: Green/Orange/Red) (Replacement unnecessary)

Earthquake monitor screen

Present time

Earthquake generation screen

Earthquake generation time, Mex. acceleration,
Seismic intensity scale, Alarm operation

Alarm hold screen

Reset button (Whole reset of alarm/buzzer)

Each setting screen

Trigger, Alarm, Date/time

Maintenance screen

Pickup test, Earthquake history

Alatm & Buzzer

Upper 3-step (ALM1-3) Individual setting,
buzzer 1-point
Acceleration : 0.1-999.9Gal
Setting interval : 0.1 Gal, 0.0 is buzzer operation OFF

Alarm & Buzzer
Reset Method

a. External reset terminal (All step reset by no-voltage a contact)
b. Automatic reset by built-in time
c. Reset button the touch panel (Available on the alarm hold screen)
1 ~ 9999sec, (Setting interval: 1-sec, 0 is automatic reset OFF)

Fault Alarm

[Power failure]
1a/1b contact switching type
Contact rating: 2A 30VDC
(Max. allowance voltage/current : 220VDC/2A)

Serial Output

For maintenance (conforms to RS232C) : MC1 (Switching type with screen control)
For external display (conforms to RS422) : MC2

Back-up Unit

Backup time ≧10min (ready time), Charging time ≦48hrs
(No function at the operation by optional power 24VDC)

Mounting Method

Wall type

Ambient Temperature

0~+50℃

Humidity Range

10~85%RH

Power Supply

100VAC±10%, ≦50VA
24VDC±10%, ≦35W(option)

Outer Dimensions

See the outside view

Painted Color

Panel:Similar to Munsell 5GY8/0.5
Case: Munsell N6.0

Weight

3kg approx.

Options to expand the function are provided.

Extemal Display ED74(for SW-74SI,SW-74)

 

Indicates Acceleration value, Seismic intensity scale and Alarm generation time.
“Color display in standard unit is a touch-panel display.
This optional external display is only an indicator without touch-panel function.

Control Unit CU-5

 

Takes out the alarm when 2-sets among 3-sets operate.
It increases the reliability of control・cut-off alarm contact output for seismic monitor.

파일명 확장자 다운로드
 SW-74[Brochure].pdf (2MB)
상호 : 주식회사 마스  |  (우)13209 경기도 성남시 중원구 사기막골로 45번길 14 우림2차 A-1610호   |   Tel : 031-735-6310 / 6320   |   Fax : 031-735-6334