LI-1500 Specifications
Current Inputs : 3 BNC connectors (used to connect LI-COR sensors)Output Channels : - Light
- Math Channels: 8 math channels (addition, subtraction, multiplication, division, natural logarithm, integration, daily integration, attenuation)
- GPS (optional)
- Prompt
- Battery Voltage
Input Channel Specifications: - Frequency Rejection : >70dB at 50 or 60 Hz (1 input channel @ sampling rates of 1, 2, 5, 10, 20Hz)
- Current Accuracy : ±0.3% of full scale reading @25°C
- Signal Ranges :
Range # | Current Range | Resolution (Typical) |
---|
1 | 0 – 0.250 µA (micro-amps) | 0.0305 nA (nano-amps) |
---|
2 | 0 – 2.50 µA (micro-amps) | 0.1525 nA (nano-amps) |
---|
3 | 0 - 25 µA (micro-amps) | 1.525 nA (nano-amps) |
---|
4 | 0 - 250 µA (micro-amps) | 15.25 nA (nano-amps) |
---|
- Raw Mode (1 – 500 Hz): Selectable Range
- Standard Modes (Continual, Manual, Daily, One Time):
- Auto range for total sampling rate ≤ 3 Hz (ex. 1 Hz sampling on 3 input channels)
- Fixed range (selectable) for total sampling rates > 3 Hz (e.g. 2 Hz sampling on 2 input channels)
Sampling Rates: - Standard Modes : 0.01 Hz, 0.1 Hz, 1 Hz, 2 Hz, 5 Hz, 10 Hz, 20 Hz
- Raw Mode : 1 – 500 Hz (1 Hz through 500 Hz in whole number increments)
Logging Rates : - Standard Modes Sampling: Every Sample, 100 msec, 200 msec, 500 msec, 1 sec, 5 sec, 10 sec, 15 sec, 30 sec, 60 sec, 100 sec, 5 min, 15 min, 30 min, 1 hr, 2 hr, 3 hr, 6 hr, 12 hr, 24 hr
- Raw Mode Sampling: Every sample (1 - 500 Hz)
Averaging : - Standard Modes : depends on sampling rate (see table below)
- Raw Mode Sampling: No averaging
Display: 128 × 64 graphics displayReal-Time Clock: - Year, Month, Day, Hour, Minute, Seconds
- Accuracy of ±3 minutes per month
Data Storage Capacity: 1 GB (FAT16 file system)Communications: USB (as mass storage device)Global Positioning System (Option) — GPS RADIONOVA® RF Antenna Module: - Horizontal position accuracy: 2.5 m CEP (50% Circular Error Probability, Open-Sky, 24hr Static, good view of the sky).
- Maximum position update rate: 1 Hz.
- GPS receiver sensitivity, autonomous acquisition: -148dBm.
- WAAS enabled receiver
- Time to first fix (TTFF), hot start: 1 second.
- TTFF, warm start: 6 seconds (typical).
- TTFF, cold start (with good view of the sky): 37 seconds at 90% probability.
Power Supply Options: - 4 “AA” size batteries
- USB, AC-DC power adapter
- USB, external battery power pack (customer supplied)
Battery Life : - 80 hours life (typical usage of 1 Hz sampling rate and logging rate)
- 40 hours life (typical usage with GPS option on)
Environmental Conditions : - Operating Temperature Range : -20 to 50°C
- Humidity Range : 0 to 95% RH (non-condensing conditions)
- Storage Temperature Range : -40 to 65°C
Size : 20.9 × 9.8 × 3.5 cm (8.2" × 3.9" × 1.4")Weight : 0.454 kg (1.0 lb) with batteries
LI-1500 Light Sensor Logger Order Informations
Part # | Product
Description | LI-1500 | Light
sensor logger | LI-1500G | Light
sensor logger with GPS | LI-1500-UW | Light
sensor logger, underwater package includes lowering frame & hard-sided
carrying case | LI-1500G-UW | Light
sensor logger with GPS, underwater package includes lowering frame &
hard-sided carrying case | | *
Consist of | | (1)
LI-1500 light sensor logger | | (4)
AA batteries | | (1)
USB cable | | (1)
AC to DC power supply adapter | | (1)
Carabiner clip | | (1)
Carrying case | | (1)
Instruction manual |
Optional Accessories
Part # | Product
Description | LI-190R-BNC-2 | Quantum sensor with
microamp output, 2m cable with BNC connector | LI-190R-BNC-5 | Quantum sensor with
microamp output, 5m cable with BNC connector | LI-190R-BNC-15 | Quantum sensor with
microamp output, 15m cable with BNC connector | LI-190R-BNC-50 | Quantum sensor with
microamp output, 50m cable with BNC connector | LI-200R-BNC-2 | Pyranometer with
microamp output, 2m cable with BNC connector | LI-200R-BNC-5 | Pyranometer with
microamp output, 5m cable with BNC connector | LI-200R-BNC-15 | Pyranometer with
microamp output, 15m cable with BNC connector | LI-200R-BNC-50 | Pyranometer with
microamp output, 50m cable with BNC connector | LI-210R-BNC-2 | Photometric sensor
with microamp output, 2m cable with BNC connector | LI-210R-BNC-5 | Photometric sensor
with microamp output, 5m cable with BNC connector | LI-210R-BNC-15 | Photometric sensor
with microamp output, 15m cable with BNC connector | LI-210R-BNC-50 | Photometric sensor
with microamp output, 50m cable with BNC connector | 2003S | Mounting &
leveling fixture for LI-COR terrestrial light sensors | LI-191R-BNC-2 | Line Quantum sensor
with microamp output, 2m cable with BNC connector | LI-191R-BNC-5 | Line Quantum sensor
with microamp output, 5m cable with BNC connector | LI-192SA | LI-192 underwater PAR
sensor with microamp output, requires underwater cable | LI-193SA | LI-193 underwater
spherical PAR sensor with microamp output, requires underwater cable | 2222UWB-3 | Underwater cable, 3m | 2222UWB-10 | Underwater cable, 10m | 2222UWB-30 | Underwater cable, 30m | 2222UWB-50 | Underwater cable, 50m | 2222UWB-100 | Underwater cable,
100m | 2009S | Lowering frame for
LI-COR underwater PAR sensors | 1500-01 | Hard-sided carrying
case |
파일명 |
확장자 |
다운로드 |
LI-1500_Spec[Brochure].pdf (397KB) |
 |
|
Light Sensor[Brochure].pdf (15MB) |
 |
|
|
상호 : 주식회사 마스 |  (우)13209 경기도 성남시 중원구 사기막골로 45번길 14 우림2차 A-1610호
|
Tel : 031-735-6310 / 6320
|
Fax : 031-735-6334
|
대표이사 / 개인정보관리책임자 : 안승만
|
사업자등록번호 : 129-86-80575
|
통신판매업등록번호 : 제2013-경기성남-0854호
|
메일 : mmm@m-m.co.kr
|
COPYRIGHT© MAS CO.,LTD. ALL RIGHTS RESERVED. |
|
|
| |