* Specifications
Construction : Body : Stainless Steel.
Touch Screen : 10.1” Widescreen LCD colour display.
Unit Operating System : Linux.
Fixing : The unit can be installed in an operator panel or in the Hydronix steel enclosure.
Power Supply : 24V DC 1.25A (40W) for Hydro-View only. Power for sensors must be calculated separately.
Web Interface : Web browsers with a screen resolution of 1024 x 600 and above.
Communications :
RS485 communication from Control System.
RS485 communication to sensor network of up to 16 sensors.
Ethernet port.
Web browser over TCP/IP network.
Optional Fieldbus port.
Optional 16 Digital Input card for digital calibration selection (16 sensors, 256 calibrations for each)
USB ports for USB memory sticks for data logging, backup / restore and system upgrade.
Ingress Protection : IP65 Front panel (when correctly installed in an operator panel or cabinet).
Operating Temperature : 0 to 50 degrees C.